NUFORM™ is pleased to provide the following US and Canadian code evaluations for your information.
United States
CONFORM™ - ICC-ES Evaluation
Evaluation Report ESR-1223
Section: 03130 - Permanent Forms
Issued September 1, 2006: Re-Issued October 1, 2008
Compliance with 2006 International Building Code ® (IBC)
Compliance with 2006 International Residential Code ® (IRC)
CF4, CF6, CF8 and CF8i Permanent Formwork
For bearing and non-bearing walls in Types I, II, III and V construction
Interior finish meets Class A rating
Exterior finish permits fire separation distance of 5 feet or less
Two hour fire resistance rating (CF6, CF8 and CF8i)
ICC-ES Evaluation ESR-1223 (PDF 345KB)

Florida
CONFORM™ - FBC Product Approval
Florida Product Approval # FL7382
Structural Components - Finished Forms
Issued December 6, 2006
Compliance with Florida Building Code (FBC) 2004
Finished polymer form for cast-in-place concrete walls. A stay-in-place form for 4", 6" or 8" thick plain or reinforced concrete walls for residential and commercial construction. Design and use to be in accordance with ICC ESR-1223 Evaluation Report. Not to be used in HVHZ.
Florida Product Approval # - FL7382 (PDF 119KB)

Canada
CONFORM™ - CCMC Evaluation
Evaluation Report 12536-R
Issued September 10, 1993: Re-evaluated May 30, 2005
Compliance with Part 9 – National Building Code of Canada (NBC) 1995 - Housing and Small Buildings
Single family dwellings
One and two storey, including foundation walls
CF walls, roofs and floors
CCMC Evaluation No 12536-R -English (PDF 234KB)

Ontario
CONFORM™ - OBC Minister’s Ruling
Minister's Ruling 95-01-20-(12536-R)
Issued January 29, 1995: Revised March 24, 2000
Compliance with Part 9 – Ontario Building Code (OBC) 1997 - Housing and Small Buildings
Approval of CCMC 12536-R for Province of Ontario
OBC Ministers Ruling No. 95-01-20 (PDF 1.2MB)

Since 1992, NUFORM™ has been actively engaged in on-going testing and research programs. The results have indicated compliance to numerous building codes around the world, including, China, Japan, Argentina, India, Europe and Russia. Testing has been conducted for hurricane criteria, seismic effects, and blast mitigation. In addition, testing and research has been conducted on many aspects that are not directly referenced in the building codes. Please contact our office should you require additional information.
The following documentation is provided for download in PDF format. You will need Adobe Acrobat Reader to view or print. Download Adobe Acrobat Reader.
|